Electrical-Photos.com en-us https://www.electrical-photos.com Sun, 28 Apr 2024 05:16:19 +0000 PhotoPost Pro 7.0 60 Fed-ex https://www.electrical-photos.com/showphoto.php/photo/311/title/fed-ex/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/311/title/fed-ex/cat/500"><img title="100_0415.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0415.JPG" alt="100_0415.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: behind patch panels Wirenuts29 Tue, 27 Jan 2009 22:27:13 +0000 fed-ex https://www.electrical-photos.com/showphoto.php/photo/310/title/fed-ex/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/310/title/fed-ex/cat/500"><img title="100_0413.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0413.JPG" alt="100_0413.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: during terminations<br /><br />3 comments Wirenuts29 Tue, 27 Jan 2009 22:27:11 +0000 fed-ex https://www.electrical-photos.com/showphoto.php/photo/309/title/fed-ex/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/309/title/fed-ex/cat/500"><img title="100_0392.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0392.JPG" alt="100_0392.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: most of cat-5 drops pulled Wirenuts29 Tue, 27 Jan 2009 22:27:09 +0000 100_0466 https://www.electrical-photos.com/showphoto.php/photo/308/title/100-0466/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/308/title/100-0466/cat/500"><img title="100_0466.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0466.JPG" alt="100_0466.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: same pipe about 6' away unreal Wirenuts29 Tue, 27 Jan 2009 22:23:10 +0000 100_0465 https://www.electrical-photos.com/showphoto.php/photo/307/title/100-0465/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/307/title/100-0465/cat/500"><img title="100_0465.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0465.JPG" alt="100_0465.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: active fire alarm system, suprisingly no ground faults or shorts, that 1/2&quot; is screwed in 2 spots in less than 2&quot; ! i know where to look if a ground fault ever comes in Wirenuts29 Tue, 27 Jan 2009 22:23:07 +0000 100_0370 https://www.electrical-photos.com/showphoto.php/photo/306/title/100-0370/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/306/title/100-0370/cat/500"><img title="100_0370.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0370.JPG" alt="100_0370.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: Open air splices, vent installed to no where? the romex that went from the switch to the vent 8' away was spliced in 3 spots, and no jb's Wirenuts29 Tue, 27 Jan 2009 22:23:05 +0000 maindisco https://www.electrical-photos.com/showphoto.php/photo/301/title/maindisco/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/301/title/maindisco/cat/500"><img title="maindisco.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/maindisco.JPG" alt="maindisco.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: This is the replacement tub of the 1200 amp service change we did, notice how tight it fits in that lean to. this thing was a monster to install. Wirenuts29 Mon, 19 Jan 2009 02:19:08 +0000 inside ct cab https://www.electrical-photos.com/showphoto.php/photo/300/title/inside-ct-cab/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/300/title/inside-ct-cab/cat/500"><img title="100_0688.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0688.JPG" alt="100_0688.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: this is part of an installation which had a neutral become energized after changing over Wirenuts29 Mon, 19 Jan 2009 02:19:06 +0000 emergency notification system https://www.electrical-photos.com/showphoto.php/photo/129/title/emergency-notification-system/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/129/title/emergency-notification-system/cat/500"><img title="100_0627.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0627.JPG" alt="100_0627.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: View of full array, and recieving antena on top of 11' mast. Wirenuts29 Fri, 16 Jan 2009 04:10:30 +0000 emergency notification system https://www.electrical-photos.com/showphoto.php/photo/128/title/emergency-notification-system/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/128/title/emergency-notification-system/cat/500"><img title="100_0613.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0613.JPG" alt="100_0613.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: Base and bottom set of 4 speakers, there are 4 more above.<br /><br />1 comment Wirenuts29 Fri, 16 Jan 2009 04:10:28 +0000 emergency notification system https://www.electrical-photos.com/showphoto.php/photo/127/title/emergency-notification-system/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/127/title/emergency-notification-system/cat/500"><img title="100_0610.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0610.JPG" alt="100_0610.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: one of 2 amplification/broadcast stations we installed on campus Wirenuts29 Fri, 16 Jan 2009 04:10:26 +0000 conventional fire alarm system upgrade https://www.electrical-photos.com/showphoto.php/photo/119/title/conventional-fire-alarm-system-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/119/title/conventional-fire-alarm-system-upgrade/cat/500"><img title="100_0376.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0376.JPG" alt="100_0376.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: new system Wirenuts29 Fri, 16 Jan 2009 04:03:11 +0000 conventional fire alarm system upgrade https://www.electrical-photos.com/showphoto.php/photo/118/title/conventional-fire-alarm-system-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/118/title/conventional-fire-alarm-system-upgrade/cat/500"><img title="100_0368.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0368.JPG" alt="100_0368.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: new panel. wires being pulled Wirenuts29 Fri, 16 Jan 2009 04:03:09 +0000 conventional fire alarm system upgrade https://www.electrical-photos.com/showphoto.php/photo/117/title/conventional-fire-alarm-system-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/117/title/conventional-fire-alarm-system-upgrade/cat/500"><img title="100_0364.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0364.JPG" alt="100_0364.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: this is the old fire alarm in this small warehouse notice the 2 60 watt heaters!! Wirenuts29 Fri, 16 Jan 2009 04:03:07 +0000 fire alarm upgrade https://www.electrical-photos.com/showphoto.php/photo/116/title/fire-alarm-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/116/title/fire-alarm-upgrade/cat/500"><img title="100_0462.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0462.JPG" alt="100_0462.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: This is the relay board within the main facp. Each rlay trips a zone in the kelron radio box above the facp. notice the orange wire. thats protocol in rhode island to trip master boxes or radio boxes. Wirenuts29 Fri, 16 Jan 2009 03:59:47 +0000 fire alarm upgrade https://www.electrical-photos.com/showphoto.php/photo/115/title/fire-alarm-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/115/title/fire-alarm-upgrade/cat/500"><img title="100_0457.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0457.JPG" alt="100_0457.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: These are 3 sync modules wired within the facp enclusure. they syncronize the three outgoing naccircuits which drive the 10 booster panels throughout this building. Wirenuts29 Fri, 16 Jan 2009 03:59:44 +0000 fire alarm upgrade https://www.electrical-photos.com/showphoto.php/photo/114/title/fire-alarm-upgrade/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/114/title/fire-alarm-upgrade/cat/500"><img title="100_0454.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/100_0454.JPG" alt="100_0454.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: This is a pic taken after we relocated the new fire alarm panel, installed one of 10 Nac Boosters, and wired the keltron radio box. This setup was about 6 feet to the left, on a tmporary strut rack while an old system was still in use Wirenuts29 Fri, 16 Jan 2009 03:59:42 +0000 Service change 600 amp to 1200 https://www.electrical-photos.com/showphoto.php/photo/113/title/service-change-600-amp-to-1200/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/113/title/service-change-600-amp-to-1200/cat/500"><img title="tapcanlabel.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/tapcanlabel.JPG" alt="tapcanlabel.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: Photo #1 new C.T. CABIET WITH 800 AMP DISTRIBUTION PANEL. Photo# 2 New tap can to re-feed existing meter stack, notice the label from the factory labeling the bussing as neutral phase a phase b phase c. this caused a huge problem as the existing meter stack was in all actuallity phase a phase b then neutral, then phase c. Bad nws for us! Wirenuts29 Fri, 16 Jan 2009 03:51:25 +0000 Service change 600 amp to 1200 https://www.electrical-photos.com/showphoto.php/photo/112/title/service-change-600-amp-to-1200/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/112/title/service-change-600-amp-to-1200/cat/500"><img title="tapcan2.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/tapcan2.JPG" alt="tapcan2.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: Photo #1 new C.T. CABIET WITH 800 AMP DISTRIBUTION PANEL. Photo# 2 New tap can to re-feed existing meter stack, notice the label from the factory labeling the bussing as neutral phase a phase b phase c. this caused a huge problem as the existing meter stack was in all actuallity phase a phase b then neutral, then phase c. Bad nws for us! Wirenuts29 Fri, 16 Jan 2009 03:51:23 +0000 Service change 600 amp to 1200 https://www.electrical-photos.com/showphoto.php/photo/111/title/service-change-600-amp-to-1200/cat/500 <a href="https://www.electrical-photos.com/showphoto.php/photo/111/title/service-change-600-amp-to-1200/cat/500"><img title="ctand800amp.JPG" border="0" src="https://www.electrical-photos.com/data/500/thumbs/ctand800amp.JPG" alt="ctand800amp.JPG" /></a><br /><br />by: Wirenuts29<br /><br />Description: Photo #1 new C.T. CABIET WITH 800 AMP DISTRIBUTION PANEL. Photo# 2 New tap can to re-feed existing meter stack, notice the label from the factory labeling the bussing as neutral phase a phase b phase c. this caused a huge problem as the existing meter stack was in all actuallity phase a phase b then neutral, then phase c. Bad nws for us! Wirenuts29 Fri, 16 Jan 2009 03:51:21 +0000